ANALYTICAL CALCULATION OF ULTRAVIOLET FLUENCE RATE IN A PHOTOREACTOR FOR THE DISINFECTION OF WATER WITH AN RADIATING CYLINDER OF INFINITE LENGTH

Purchase PDF

Published: 2017-08-19

Page: 55-71


ROMAN ILINSKY *

Joint Stock Company Svarog, Stromynka Street 18, Moscow 107014, Russia.

ANDREY ULYANOV

Joint Stock Company Svarog, Stromynka Street 18, Moscow 107014, Russia

*Author to whom correspondence should be addressed.


Abstract

Fluent rate calculation in photochemical reactor using ultraviolet (UV) to disinfect water with diffusely radiating cylinder of infinite length as a source of UV is considered. The dependence of fluence rate from diameter of radiating cylinder is analytically examined. Extreme case with radiating cylinder diameter tending to zero is shown. Based on ”effective interval” comparison of fluence rate for cylinders of finite and infinite length is reported. For numerical integration in fluence rate calculations, it is suggested to use Chebushev method.

Keywords: Disinfection, photoreactor, ultraviolet, UV fluence rate, radiating cylinder


How to Cite

ILINSKY, R., & ULYANOV, A. (2017). ANALYTICAL CALCULATION OF ULTRAVIOLET FLUENCE RATE IN A PHOTOREACTOR FOR THE DISINFECTION OF WATER WITH AN RADIATING CYLINDER OF INFINITE LENGTH. Journal of Applied Chemical Science International, 8(2), 55–71. Retrieved from https://ikprress.org/index.php/JACSI/article/view/3794